On-line Analyzers Residual Chlorine Chlorine Dioxide Ozone Analyzer

Tsanangudzo Pfupi:

★ Muenzaniso Nhamba: CLG-2096Pro/P

Mamiriro ezvinhu: Klorini yemahara, chlorine dioxide, ozone yakanyungudika

★Communication Protocol: Modbus RTU(RS485)

★ Simba rekupa: 100-240V (24V imwe nzira)

★ Measuring Principle: Constant voltage


  • facebook
  • sns02
  • sns04

Product Detail

Iyo CLG-2096Pro/P yepamhepo yakasara chlorine otomatiki analyzer ichangobva kugadzirwa yakangwara yepamhepo analog chiridzwa chakazvimiririra kutsvagirwa uye kugadzirwa neBoqu Instrument Company. Inoshandisa analog yakasara chlorine electrode kuyera nemazvo uye kuratidza yemahara chlorine (inosanganisira hypochlorous acid uye zvinobva mairi), chlorine dioxide, uye ozone iripo mune chlorine-ine mhinduro. Chiridzwa chinotaurirana nemidziyo yekunze yakadai sePLCs kuburikidza neRS485 ichishandisa Modbus RTU protocol, ichipa zvakanakira senge kukurumidza kutaurirana kumhanya, kwakaringana kutapurirana data, mashandiro akazara, kuita kwakadzikama, kushandiswa kwemushandisi-ushamwari, kuderera kwesimba rekushandisa, uye yakakwirira mwero yekuchengetedza uye kuvimbika.

Features:
1. Nehupamhi hwepamusoro kusvika ku0.2%.
2. Inopa zvingasarudzwa zviviri zvinosarudzwa: 4-20 mA uye RS-485.
3. Nzira mbiri-relay inopa mabasa matatu akasiyana, zvichiita kuti zvive nyore pakubatanidzwa kwehurongwa.
4. Yakagadzirwa neyakasanganiswa nzira yemvura uye inokurumidza-kubatanidza fittings, inoita kuti zvive nyore uye zvinobudirira kuiswa.
5. Chigadzirwa chacho chinokwanisa kuyera zvikamu zvitatu-zvakasara chlorine, chlorine dioxide, uye ozone-uye inobvumira vashandisi kuchinja pakati pezvipimo zvekuyera sezvinodiwa.

Applications:
Inogona kushandiswa zvakanyanya mumabasa emvura, kugadzira chikafu, kurapwa uye hutano, aquaculture, uye kurapwa kwetsvina yekuenderera mberi kwekutarisa kweyakasara chlorine mumhinduro.

TECHNICAL PARAMETERS

Model

CLG-2096Pro/P

Kuyera Zvinhu

Yemahara chlorine, chlorine dioxide, ozone

Chiyero Nheyo

Constant voltage

Measurement Range

0~2 mg/L(ppm) -5~130.0℃

Kururama

± 10% kana ± 0.05 mg/L, chero chikuru

Magetsi

100-240V (24V imwe nzira)

Signal Output

Imwe-nzira RS485, mbiri-nzira 4-20mA

Tembiricha Muripo

0-50 ℃

Flow

180-500mL / min

Zvinodiwa Zvemhando Yemvura

Conductivity> 50us/cm

Inlet/Drain Diameter

Inlet: 6mm ; Mvura: 10mm

Dimension

500mm*400mm*200mm(H×W×D)

CL-2096-01

Model

CL-2096-01

Product

Residual chlorine sensor

Range

0.00 ~ 20.00mg/L
Resolution

0.01mg/L

Kushanda tembiricha

0 ~ 60 ℃

Sensor zvinhu

girazi, mhete yeplatinamu

Connection

PG13.5 thread

Cable

5meter, yakaderera ruzha tambo.

Application

mvura yekunwa, swimming pool etc